ASTM F2170 Moisture Testing & Vapor Barrier Systems in Tampa Bay, FL
Fill out the form — we'll reply within 24 hours.
Moisture mitigation is the process of testing concrete for moisture vapor emissions and, if necessary, installing a barrier system to prevent ground moisture from damaging floor coatings. In Tampa Bay, where concrete slabs sit directly on damp Florida soil and the water table is often just feet below the surface, moisture vapor transmission is the single most common cause of coating failure.
When moisture vapor pushes up through a concrete slab and encounters an impermeable coating like epoxy or polyaspartic, it builds pressure at the bond line. The result is blistering, delamination, and — eventually — total coating failure. This typically happens 6–18 months after installation, just outside the period when most contractors will respond.
We use ASTM F2170 relative humidity testing — the industry standard — to measure moisture levels within the slab. If levels exceed the coating manufacturer's specifications, we install an appropriate moisture-mitigation system before any coating goes down.
Moisture vapor is the #1 cause of epoxy, polyaspartic, and urethane coating failure in Florida. Mitigation stops it at the source.
We use ASTM F2170 in-situ relative humidity probes — the same testing method specified by manufacturers and recommended by the American Concrete Institute.
A moisture-mitigation system costs a fraction of what you'll spend stripping and replacing a failed coating. It's the cheapest insurance you can buy for your floor.
Many coating manufacturers void their warranty if moisture testing isn't performed. Mitigation ensures your warranty stays valid.
We offer epoxy-based moisture vapor barriers, urethane vapor barriers, and cementitious toppings depending on your slab's moisture level and coating choice.
A properly installed moisture-mitigation system permanently blocks vapor transmission. Your coating is protected for its full lifespan.
ASTM F2170 is the gold standard for concrete moisture testing. Unlike older calcium chloride tests that only measure surface moisture, F2170 measures the actual relative humidity within the slab.
The process:
1. Small holes are drilled into the concrete slab at the depth specified by the testing standard (typically 40% of slab depth).
2. Plastic sleeves are inserted into the holes and sealed to prevent surface moisture from affecting the reading.
3. RH probes are placed in the sleeves and left for a stabilization period (typically 24–72 hours).
4. Readings are taken and compared to the coating manufacturer's maximum allowable RH level (typically 80–85% for most epoxy systems).
5. If readings exceed the threshold, we recommend an appropriate moisture-mitigation system.
Why this matters: In Tampa Bay, it's common to find RH levels of 90–95% in garage and ground-floor slabs. Without testing and mitigation, coating failure is virtually guaranteed.
Epoxy Moisture Vapor Barriers (MVB): 100% solids epoxy systems applied at high film thickness (15–25 mils) that block vapor transmission. Compatible with most epoxy and polyaspartic topcoats. Best for residential and light commercial.
Polyurethane Vapor Barriers: Flexible moisture barriers that bridge hairline cracks and handle slab movement. Ideal for commercial and industrial applications where the coating system includes a urethane topcoat.
Cementitious Moisture Mitigation: A cement-based topping (typically 1/4"–1/2" thick) that encapsulates the slab surface and blocks vapor. Best for slabs with very high moisture readings or where a new wear surface is also desired.
Which system is right for your project? We recommend the system based on your slab's measured RH level, the coating system being installed, and your budget. During your free consultation, we'll explain the options and provide firm pricing.
You may need moisture testing and mitigation if:
• Your garage or building is on a concrete slab with no vapor barrier beneath it • The slab is less than 6 months old • You see white efflorescence (powdery deposits) on the concrete surface • Existing coatings are blistering or delaminating — especially in patterns that suggest vapor pressure • Your home or business is in a low-lying area or near the water table • The slab feels damp to the touch, especially during Tampa Bay's humid summer months
If any of these apply, ASTM F2170 testing should be the first step before any coating work begins. We offer testing as a standalone service, even if you choose another contractor for the coating installation.
How much does moisture mitigation cost in Tampa Bay? ASTM F2170 moisture testing typically costs $200–$400 for a residential slab. Mitigation systems range from $2–$5 per sq. ft., depending on the system type and moisture level. We provide itemized estimates.
Is moisture testing required for every floor coating project? Yes — we test every slab before coating, without exception. In Florida, the cost of testing is minuscule compared to the cost of a failed floor. No reputable contractor should skip this step.
Can moisture issues be fixed after the coating has been applied? Not without removing the coating. Once an impermeable coating is applied over a slab with moisture issues, the vapor builds pressure beneath the coating, causing blisters and delamination. The coating must be removed, the slab tested, and a mitigation system installed before re-coating.
How long does moisture mitigation take? Testing takes 24–72 hours for probe stabilization. If mitigation is needed, the system is typically installed in 1–2 days for a residential garage, then must cure before the coating can be applied.
Does every coating contractor in Tampa Bay perform moisture testing? No — and that's why we see so many failed epoxy floors. Many contractors skip testing because it adds time and cost to the estimate. We never skip it because we want your floor to last.
See examples of our moisture mitigation projects

Explore our full range of concrete coating solutions
Prep work after mitigation installation
Remove failed moisture-damaged coatings
Repair cracks after moisture treatment
Coating systems compatible with mitigation
Common questions about our moisture mitigation service
ASTM F2170 is the standard test method for measuring relative humidity in concrete slabs using in-situ probes. It's the most accurate way to determine if a slab has moisture levels safe for coating application.
Contact us today for a free consultation and quote for your moisture mitigation project